Fusheng Air Compressors · Screw / Oil-Free / PM VSD / Compressed Air System Solutions Service Hotline 400-820-8795 ChineseEnglishJapaneseGermanSpanishKoreanItalianFrenchRussianPortuguese

EPM+-T Two-Stage Oil-Cooled PM VSD Screw Air Compressors

ESSENCE Two-Stage Screw Air Compressors Model EPM+-T
@essence_base@ @em_tail@
EPM+-T Models
EPM+55A/W-*T EPM+75A/W-*T EPM+90A/W-*T
0.8MPa
m3/min 4.80~12.00 6.60~16.50 8.00~20.00
1.0MPa
m3/min 4.28~10.70 5.84~14.60 6.76~16.90
1.25MPa
m3/min 3.76~9.40 5.16~12.90 5.84~14.60
Power
kW 55 75 90
Screw air compressorPM VSD air compressor

ESSENCE EPM+-T Two-Stage PM VSD Compressor: 55~90kW Oil-Cooled Design

In the 55~90kW power band, many plants actually have substantial air demand, but the pressure they need shifts with each product changeover — today it is 0.7MPa for routine pneumatics, tomorrow it may be 1.25MPa for a high-pressure process. At that point, whether a machine can stay efficient across several pressure points becomes the deciding factor in selection.

The ESSENCE EPM+-T two-stage, oil-cooled PM VSD screw air compressor is built for exactly this range. It comes in three power steps — EPM+55A/W-*T, EPM+75A/W-*T and EPM+90A/W-*T — covering 55~90kW, with a working pressure of 0.7~1.25MPa and rated air delivery given for four pressure points. ESSENCE is a wholly owned subsidiary of Fusheng Group, and its products are backed by Fusheng's technology and service system; this model is positioned on strong value and consistent quality. Voltage and frequency span 220/380/415/440V at 50/60Hz, so it suits different regional power systems.

Two-Stage Compression: Why It Saves Power

Compressing air in a screw machine generates a great deal of heat: once compressed, the air is hotter and bulkier, and pushing it further becomes harder. Two-stage compression splits a single compression into two steps and places cooling between them, so the air entering the second stage is first cooled and reduced in volume — which lowers the compression work the second stage has to perform.

The direct benefit to the user is better energy efficiency at the same power rating — the advantage of the two-stage layout is especially clear at higher pressures. That is why the EPM+-T belongs to the two-stage family. For a machine that runs continuously, every bit of compression work saved eventually shows up on the electricity bill.

Oil-Cooled Design: Keeping Motor Temperature Down

Permanent magnet motors are sensitive to temperature, and prolonged heat carries a risk of demagnetisation that undermines both efficiency and reliability. The "oil-cooled" tag in the EPM+-T name signals that cooling plays a major role in how the package manages heat. Bringing motor and airend cooling into a single oil circuit helps hold the temperature rise within a sensible range in workshops that run continuously and get hot. For users who run long shifts without a climate-controlled machine room, this is worth noting.

Four Pressure Points, One Clear Table

One practical feature of this model is that air delivery is listed for each pressure, so selection can be checked directly against it:

Model0.7MPa0.8MPa1.0MPa1.25MPa
EPM+555.12~12.804.80~12.004.28~10.703.76~9.40
EPM+757.00~17.506.60~16.505.84~14.605.16~12.90
EPM+908.32~20.808.00~20.006.76~16.905.84~14.60

(Air delivery in m³/min)

The table shows one clear pattern: the higher the pressure, the lower the air delivery from the same model. So when selecting, do not go by the maximum air delivery alone — first fix the working pressure you use most, then read the air delivery range for that pressure.

Construction and Dimensions

The EPM+-T uses coupling drive, and the air outlet is either G2 or a DN80 square flange depending on the model. Physically, the three power steps are close in size: length 2250/2250/2300mm, width 1344/1344/1450mm, height 1694/1694/1750mm, net weight 2350/2520/2950kg. The compact overall dimensions make the units easy to place and swap within an existing compressor room. Notably, the three power steps differ very little in footprint, which means a plant expanding later can move up to a larger model without re-planning the room layout, keeping modification costs relatively contained.

Technical Specifications

ItemSpecification
Power55 / 75 / 90 kW
Working pressure0.7 ~ 1.25 MPa
Air delivery3.76 ~ 20.80 m³/min
Starting methodPM VSD start
Voltage / frequency220/380/415/440V, 50/60Hz
DriveCoupling drive
Aftercooler outlet temperature≤ ambient temperature + 15°C
Air outletG2 / DN80 square flange
Dimensions (L×W×H)2250~2300 × 1344~1450 × 1694~1750 mm
Net weight2350 ~ 2950 kg

PM VSD starting lets the unit's speed follow air demand continuously, avoiding the waste of blowing off at no load. Holding the aftercooler outlet temperature within +15°C of ambient eases the load on downstream refrigerated dryers and filters. And because the air outlet is either G2 or a DN80 square flange depending on the model, connecting to plant piping of different sizes is straightforward.

Who It Suits

  • Plants with moderate air demand and shifting pressure needs: air delivery data is given for all four pressure points;
  • Production lines that run continuously: two-stage compression shows a clearer efficiency edge at higher pressures;
  • Workshops sensitive to power costs with fluctuating loads: PM VSD modulation cuts no-load waste;
  • Compressor rooms with limited space that need to replace existing equipment: the compact footprint is easy to work with.

Selection Advice

  1. Fix the pressure you use most: whether that is 0.7 or 1.0MPa directly determines the air delivery range available to you;
  2. Match air delivery to the pressure point: do not use maximum air delivery as the basis for selection;
  3. Leave room to grow: lines may be expanded, so size the machine with the future in mind;
  4. Plan the treatment equipment at the same time: configure drying and filtration to process requirements and plan them together with the compressor.

Conclusion

In the crowded 55~90kW band, the EPM+-T brings two-stage compression and oil-cooled design together so that efficiency and reliability are addressed as one. If your plant does not work at a single fixed pressure, a model with solid data behind every pressure point is far easier to choose with confidence.

Technical Specifications

EPM+-T ModelsEPM+55A/W-*T EPM+75A/W-*T EPM+90A/W-*T
Air Delivery0.7MPa m3/min 5.12~12.80 7.00~17.50 8.32~20.80
0.8MPam3/min 4.80~12.00 6.60~16.50 8.00~20.00
1.0MPam3/min 4.28~10.70 5.84~14.60 6.76~16.90
1.25MPam3/min 3.76~9.40 5.16~12.90 5.84~14.60
PowerkW 55 75 90
Starting MethodType: PM VSD start
Voltage / FrequencyV/Hz 220/380/415/440V、50/60Hz
Aftercooler Outlet Temperature°C ≤ ambient temperature +15 °C
Drive MethodCoupling drive
Air Outletin. G2 / G2 / Square flange DN80
Lengthmm 2250 2250 2300
Widthmm 1344 1344 1450
Heightmm 1694 1694 1750
Net Weightkg 2350 2520 2950
Working Pressure0.7~1.25 MPa; air delivery 3.76~20.80 m³/min; power range 55~90 kW
Working Pressure0.7~1.25 MPa
Air Delivery3.76~20.80 m³/min
Power Range55~90 kW
GALLERY

Product Gallery

RELATED

Related Products

Need technical data or a quote for the EPM+-T?

Give us your working pressure, air demand and site conditions, and we will confirm the model and configuration

400-820-8795