Air demand in a workshop is never constant. Consumption is low at the start of the morning shift, high at full load around midday, and drops again at night. A conventional fixed-speed air compressor runs at the same speed no matter how much air is used, and the surplus can only be blown off — that energy is simply wasted. The value of PM VSD is that it lets the machine "produce only what is used."
The ESSENCE FRV series PM VSD screw air compressor is built around exactly this logic. It covers 7.5-75 kW, with air delivery of 0.25-13.8 m³/min and working pressure of 0.7-1.25 MPa. It uses PM VSD start and coaxial direct drive, covering the air demand of everything from mid-sized workshops to larger production lines.
A fixed-speed machine regulates by load/unload: it unloads once pressure is reached and loads again when pressure falls. With this method the motor runs at full speed throughout, and the energy consumed while unloaded produces no useful air.
FRV uses PM VSD start, and motor speed varies continuously with air demand:
The more pronounced the demand fluctuation, the more the benefit of VSD regulation stands out — especially for workshops on one or two shifts, or with frequent product changeovers. One caveat: if a VSD model runs at very low load for long periods, attention should still be paid to the heat dissipation and lubrication of the airend and motor, with maintenance carried out as the manual requires, so the VSD advantage can be sustained over the long term.
FRV covers pressures from 0.7 MPa to 1.25 MPa, with the same model delivering different air volumes at four pressure ratings. Taking FRV22A as an example, air delivery reaches 3.80 m³/min at 0.7 MPa and 3.00 m³/min at 1.25 MPa.
A wider pressure range means greater adaptability: ordinary pneumatic equipment uses 0.7-0.8 MPa, while processes such as laser cutting, bottle blowing, and high-pressure testing need higher pressures. In selection, first determine the actual working pressure, then match air delivery at that pressure — pressure and air delivery trade off against each other, so it is not advisable to simply take the maximum value.
The specifications list the drive as coaxial direct drive. The motor connects directly to the airend, reducing intermediate transmission links and raising drive efficiency, while also doing away with day-to-day maintenance such as belt aging, tensioning, and replacement.
The aftercooler outlet temperature is held at ≤ ambient + 15°C, an indicator that bears on the load of downstream refrigerated dryers and filters: the better the discharge temperature is controlled, the lighter the burden on treatment equipment, and the lower the energy consumption and failure rate across the whole air system.
Voltage/frequency is 380V, 50/60Hz, matching 380V industrial power supply standards and accommodating both 50Hz and 60Hz.
The FRV series covers nine power tiers, from FRV08A to FRV75A, running continuously from 7.5 kW to 75 kW, with air delivery rising with power and air outlets from G1 to G2. Air delivery for each model at the four pressure ratings of 0.7, 0.8, 1.0, and 1.25 MPa can be found in the full specification table at the bottom of the page.
| Item | Specification |
|---|---|
| Working pressure | 0.7 ~ 1.25 MPa |
| Air delivery | 0.25 ~ 13.8 m³/min |
| Power range | 7.5 ~ 75 kW |
| Start method | PM VSD start |
| Voltage/frequency | 380V, 50/60Hz |
| Drive | Coaxial direct drive |
| Aftercooler outlet temperature | ≤ ambient + 15°C |
| Air outlet | G1 ~ G2 |
The point of PM VSD is not an extra line on a specification sheet, but letting the equipment genuinely follow air demand. With 7.5-75 kW power coverage, a wide 0.7-1.25 MPa pressure range, and coaxial direct drive, the ESSENCE FRV series offers an on-demand air supply solution for workshops with pronounced fluctuation. As a brand under Fusheng Group, ESSENCE draws on the group's accumulated R&D and service systems, giving selection and follow-up service a firmer footing.
| Starting Method | Type: PM VSD start |
|---|---|
| Voltage / Frequency | V/Hz 380、50/60Hz |
| Aftercooler Outlet Temperature | °C ≤ ambient temperature +15 °C |
| Drive Method | Coaxial direct drive |
| Working Pressure | 0.7~1.25 MPa; air delivery 0.25~13.8 m³/min; power range 7.5~75 kW |
| Working Pressure | 0.7~1.25 MPa |
| Air Delivery | 0.25~13.8 m³/min |
| Power Range | 7.5~75 kW |





Give us your working pressure, air demand and site conditions, and we will confirm the model and configuration