Fusheng Air Compressors · Screw / Oil-Free / PM VSD / Compressed Air System Solutions Service Hotline 400-820-8795 ChineseEnglishJapaneseGermanSpanishKoreanItalianFrenchRussianPortuguese

GW Series Oil-Free Screw Air Compressors

Fusheng Oil-Free Screw Air Compressors Model GW Series
The Fusheng GW series oil-free scroll air compressor is completely oil-free, delivering pure air quietly and in a compact footprint. It is ideal for dental clinics, precision laboratories and other sites that need high-quality compressed air.
Specification Overview
Working pressure 0.7~1.0 MPa, air delivery 0.345~3.52 m³/min, power 4~37 kW
Oil-free air compressorOn-site air compressor

Fully Oil-Free, Quiet: Fusheng GW Series, 0.345–3.52 m³/min

In places such as dental clinics, precision laboratories and testing centres, compressed air may come into direct contact with instruments, samples or test subjects. Even a trace of oil in the air supply can affect the safety of treatment and the accuracy of results. At the same time, these settings are usually located within office or clinical areas, where the demands on noise and footprint are far stricter than in an industrial workshop.

The Fusheng GW Series oil-free air compressor is made for exactly this kind of small but demanding air requirement. It is fully oil-free and produces pure air, and it is characterised by low noise and a small footprint. The series covers a working pressure of 0.7–1.0 MPa, air delivery of 0.345–3.52 m³/min and power from 4 to 37 kW, making it a typical on-site compressor.

What Fully Oil-Free Actually Means

The cleanliness of compressed air is usually judged by oil content, dew point and dust content, and oil content is the hardest of these to correct. Even with multi-stage filtration, an oil-injected compressor only reduces oil to a lower level; the filter elements gradually saturate with use, need regular replacement and carry a risk of failure.

The GW Series is a fully oil-free design: no lubricating oil is introduced in the compression stage, so the compressed air is oil-free at the source. For oil-sensitive settings such as dental clinics and laboratories, this moves risk control upstream and reduces dependence on downstream filter elements.

Fully oil-free is a property of the machine itself, not something achieved by adding equipment later. This is the fundamental difference from an oil-injected machine with multi-stage filtration: the former has no oil by design, while the latter does its best to remove oil.

Low Noise, Small Footprint: Why It Can Sit in the Treatment Room

Conventional compressors are noisy and usually need a dedicated machine room, but clinics and laboratories often have neither the space nor the need to build a separate air station. The low noise and small footprint of the GW Series make it better suited to being installed right next to the point of use:

  • no construction or floor-space cost for a separate machine room;
  • shorter piping, reducing pressure loss and potential leak points;
  • air supplied nearby, giving more stable pressure and faster response to demand.

This is why it is positioned as an on-site compressor: the air source does not have to be hidden away, but can sit right where it is needed. For a clinic or laboratory short on space, what is saved is often not just a machine room but also the piping work and ongoing maintenance that come with it.

From 4 kW to 37 kW, Covering Small to Mid-Sized Sites

With power from 4 to 37 kW and air delivery of 0.345–3.52 m³/min, the GW Series spans a wide enough range to cover air demand from a single dental chair or a one-room laboratory to a small workshop with several workstations. The specification table lists GW04E series models at three pressure points — 0.7 MPa, 0.8 MPa and 1.0 MPa — so users can pick the model that matches their actual working pressure.

If air demand grows later, a higher-power model can be chosen within the same series, without switching brands or rebuilding the whole air supply scheme — an advantage that leaves room for upgrading for clinics and laboratories that are still growing.

Bear in mind that oil-free is only one dimension of air quality. If the process also has requirements for dew point or dust content, the corresponding drying and filtration equipment still needs to be installed downstream to form a complete air supply scheme.

Installation and Operation Points for On-Site Units

Placing a compressor near the point of use is not simply a matter of moving it. There are several points to watch when installing and operating an on-site unit:

  • Ventilation and heat dissipation: the unit is small, but the space for heat dissipation cannot be cut — leave enough intake and exhaust clearance around the cabinet;
  • Intake environment: oil-free models are sensitive to intake air cleanliness, so avoid installing them in areas with high dust or oil-mist concentrations;
  • Drainage and maintenance: condensate from the compressed air must be drained regularly, and filter checks and drain-valve cleaning should be part of routine maintenance;
  • Noise and vibration: although noise is low, anti-vibration and sound-insulation measures are still recommended when the unit is placed next to a treatment room or laboratory.

These details may seem trivial, but they directly determine whether the unit can run quietly and steadily over the long term.

Technical Specifications

ItemSpecification
Working pressure0.7–1.0 MPa
Air delivery0.345–3.52 m³/min
Power range4–37 kW
CompressionFully oil-free
PositioningOn-site compressor
Models in tableGW04E series
Pressure points0.7 / 0.8 / 1.0 MPa

Suitable Industries and Applications

  • Air supply for dental clinics and oral treatment equipment;
  • Precision laboratories and testing institutions;
  • Small clean-air points in pharmaceuticals, food and similar fields;
  • Small workstations sensitive to air cleanliness, such as electronics and instruments;
  • Sites with limited space that need the air source installed nearby.

Selection Advice

  1. Confirm cleanliness and working pressure first: establish whether fully oil-free is required and what working pressure the pneumatic equipment needs;
  2. Estimate air delivery from the workstations running at the same time: combine the number of devices and the air consumption of each so the model is neither too small nor too large;
  3. Leave space for cooling and servicing when installing on site: a small footprint does not mean it can be pushed into a corner against a wall — ventilation directly affects running stability;
  4. Configure air treatment to the process requirements: oil-free solves the oil-content issue, but dew point and dust content still need to be addressed separately.

Conclusion

For small, cleanliness-sensitive sites, the criteria for air supply equipment are plain: clean enough, quiet enough, fits in place and easy to service. The GW Series starts from fully oil-free, trades low noise and a small footprint for freedom of installation, and uses a 4–37 kW power range to catch on-site demand at different scales. When the air source can be placed close by, supplying air becomes simple.

Technical Specifications

ModelProduct ModelWorking PressureMPaAir Deliverym"/minPowerDimensionsmmkgWeightConnection SizeNoise (1.5 m in front)dB(A)
GW04E-7B0.70.44
GW04E-8B0.804253.7 × 11000×525×5051201/2"52
GW04E-10B1.00345
GW04E-7P0.70.44
GW04E-8P0.804253.7 x 1940×525×8401501/2"
GW04E-10P1.00345
GW04A-7B0.70.44
GW04A-8B0.804253.7 × 1640×604×8951701/2"49
GW04A-10B1.00345
GW04A-7P0.70.44
GW04A-8P0.804253.7 × 11550×604×15103251/2"49
GW04A-10P1.00345
GW08A-7B0.70.88
GW08A-8B0.80.853.7 × 21020×750×16454403/4"
GW08A-10B1.00.69
GW11A-7B0.71.32
GW11A-8B0.812753.7 × 31600×750×183065057
GW11A-10B1.01035
GW15A-7B0.71.76
GW15A-8B0.81.703.7 × 41600×750×183072059
GW15A-10B1.01.38
2. Models with the suffix "P" include an air receiver.
Source: official specification chart
SPEC CHART

Specification Charts

Official specification charts for this product — click to enlarge

GALLERY

Product Gallery

RELATED

Related Products

Need technical data or a quote for the GW Series?

Give us your working pressure, air demand and site conditions, and we will confirm the model and configuration

400-820-8795