CSR Series Screw Refrigerant Compressors
The Fusheng CSR series screw refrigerant compressor uses high-efficiency …
5 products in this category
The Fusheng CSR series screw refrigerant compressor uses high-efficiency …
The CSRL series is a refrigeration compressor developed by Fusheng specif…
The SRT series single-machine two-stage heat pump compressor has earned r…
Can be connected in parallel to meet high cooling capacity demands. Low n…
The Fusheng SST scroll-screw single-machine two-stage refrigeration compr…
In cold-chain logistics, commercial refrigeration and air conditioning, and industrial refrigeration, the common heart of these systems is the refrigerant compressor. Fusheng offers 5 refrigerant compressors, all screw type, covering duties from refrigeration and air conditioning to medium- and low-temperature freezing and single-machine two-stage operation, with refrigerants including R22, R404A, R407C, R507 and R134a.
| Series | Displacement | Applicable refrigerant | Positioning |
|---|---|---|---|
| CSR | 120–1950 m³/hr | R22 / R404A / R407C / R507 | Wide displacement, general refrigeration and air conditioning |
| CSRL / SRL | 85–472 m³/hr | R22 / R404A / R507 | Medium and low temperature, 7.5 to -45 °C |
| SRT | 144/60–759/300 m³/hr | Refrigeration R22/R404A; heat pump R134a | Single-machine two-stage, covering both refrigeration and heat pump |
| SDL | 120–655 m³/hr | R22 / R404A / R507 | Evaporating temperature down to -60 / -65 °C |
| SST | 100–170 m³/hr | R22 / R404A / R507 | Single-machine two-stage, screw plus scroll |
Several series use the Fusheng 5:6 asymmetric rotor profile, with rotors formed by precision machining; they support VSD operation and an economizer port, and can be run in parallel to meet large cooling capacity requirements. Some series are tested before shipment through a refrigerant system that simulates the user's operating conditions, and use high-efficiency motors with a built-in PTC thermistor to monitor coil temperature. Each series differs in evaporating temperature and refrigerant compatibility, which are key parameters to check one by one during selection.
The five series range from general refrigeration to deep low temperature, and from single-stage to single-machine two-stage, broadly covering the main duties of refrigeration systems. The first step in selection is to define the evaporating temperature and refrigerant, then determine the specific model together with the cooling capacity and installation conditions.